Torpfosten Rechner
Prüfe ob 9x9 oder 14x14 Holz- bzw. Stahlpfosten nötig sind, inkl. Fundamenttiefe und Betonmenge nach Torgewicht.
Torpfosten Dimensionierung & Fundament
Gib deine Maße ein, das Ergebnis aktualisiert sich beim Tippen.
Übersicht
Torpfosten tragen dynamische Lasten und Hebelkräfte, denen normale Zaunpfosten nie ausgesetzt sind. Bereits 5 mm Biegung lässt Falle und Schloss klemmen.
Dieser Rechner analysiert Flügelbreite und Gewicht, um die Mindestquerschnitte und Fundamentabmessungen zu bestimmen.
Annahmen
- Gate leaf widths over 5 feet or weights over 120 pounds mandate a minimum 6x6 structural post.
- Footing depths are engineered to resist overturning moment and cantilevered lateral load.
- Concrete footing diameter is at least 12 to 14 inches with full perimeter encasement.
- Posts are rated for ground contact (UC4A treated or heavy-gauge steel).
Häufige Fehler
- Einsatz von Standard 9x9 Pfosten für Tore mit mehr als 1,2 m Breite oder über 50 kg Gewicht.
- Ausheben zu flacher Fundamente, die unter der Hebelwirkung des offenen Tores nachgeben.
- Torflügel einhangen, bevor der Fundamentbeton mindestens 72 Stunden abgebunden hat.
- Schrauben ohne Vorbohren nahe der Pfostenkante eindrehen und das Holz spalten.
Nächster Schritt
- Rechner für Betonsäcke Rechnen Sie den Lochdurchmesser, die Tiefe und die Anzahl der Löcher in eine Beutelanzahl für 50-, 60- und 80-Pfund-Mischungen um, wobei die Volumenberechnung angezeigt wird.
- Zaunpfostenrechner Berechnen Sie Linienpfosten, Eckpfosten und Endpfosten anhand der Lauflänge und des Abstands, wobei Beton für jeden Pfosten in der Abnahme enthalten ist.
Verwandte Rechner
- Doppeltor Rechner Berechne die exakte Rahmenbreite beider Flügel für zweiflügelige Einfahrtstore abzgl. Bander und Mittelfalz.
- Zauntor-Rechner Planen Sie die Öffnung, die Pfosten, die sie tragen, und die Hardware, die ein Zauntor benötigt, für ein Lauftor oder ein Tor mit Doppelantrieb.
- Pfostenloch Rechner Berechne Aushubdurchmesser, Tiefe, Zylindervolumen und Trockenbetonsacke für standfeste Zaunfundamente.
Weiterführende Lektüre
Ausführliche Leitfäden
Kaufratgeber
A gate post calculator answers a question that a general post spacing or post depth calculator cannot, because gate posts are not carrying the same load as the line posts spaced evenly along the rest of a fence run. A line post resists lateral wind push and the occasional lean against it. A gate post resists a constant cantilevered load every time the gate is swung open and left standing, plus the repeated shock of a leaf being slammed shut, and that combination of standing torque and impact is what makes a gate post flex, lean, or eventually fail where a line post of the same size would hold fine for decades. This calculator works from the gate leaf width and weight to the post size, the hole depth, and the concrete volume needed to resist that overturning load rather than reusing the line post numbers out of convenience, which is the shortcut most DIY gate builds take and the one that causes trouble within a year or two.
The core decision is whether a 4x4 is enough or whether the post needs to step up to a 6x6 or an equivalent steel post. As a rough rule, any gate leaf wider than about 5 feet or any leaf heavier than roughly 120 pounds pushes the post selection toward the larger 6x6 size, since the leverage a wide or heavy leaf puts on a 4x4 post is enough to work it loose from the concrete over a few seasons even if the post looked solid on installation day. Fence height feeds the hole depth this calculator recommends, not the post size itself, since a tall but light and narrow gate leaf puts no more sideways leverage on the post than a short one does. Steel is a reasonable alternative to wood where rigidity matters more than matching the rest of a wood fence: schedule 40 galvanized pipe or heavy square tubing resists warping in a way a wood post cannot, particularly on a post that is going to see daily use for years and carry the same leaf open and shut thousands of times. For the fence itself once the gate post sizing is settled, the fence post calculator handles the lighter line post count and spacing for the rest of the run, which is a different and simpler calculation than the gate post problem this tool solves.
Depth matters as much as post size, and it is the detail most often shortchanged on a DIY gate. Gate posts commonly go in 36 to 48 inches deep, roughly a foot deeper than a standard line post, or to the regional frost line if that number is greater, because the overturning moment from a swinging leaf acts on the post like a lever and a shallow footing simply does not have enough soil and concrete bearing against it to resist that force. A 14 inch diameter hole at 36 inches deep typically takes somewhere around 5 to 6 bags of 60 pound concrete mix, and the concrete bags calculator and fence post hole calculator are useful for working out the exact volume once the hole diameter and depth for a particular gate post are settled, since gate post holes are consistently larger than line post holes and running short on mix mid-pour on a gate post is a worse problem than on a line post because the hole has to be filled in one continuous pour for the concrete to cure as a solid mass. The concrete also needs real cure time before the gate is hung, commonly 48 to 72 hours at minimum, because loading a gate onto wet concrete pulls the post out of plumb before it has reached anywhere near its full strength.
A few related decisions round out a gate post build. Wide driveway or equipment gates are usually better served by splitting the opening into two leaves on two separate hinge posts rather than one oversized leaf on a single post, which is covered directly by the double gate calculator and its own per-leaf clearance math. The opening and hardware for either a single or double gate are covered together by the fence gate calculator, and once the panel width itself needs converting from a clear opening, the gate width calculator handles that conversion directly. For heavier gates or long spans, linking the tops of both gate posts with an overhead beam is a common way to resist the inward sagging that develops over years of use, a detail covered along with hinge and hardware selection in the gate hardware and framing guide. The full set of gate sizing tools lives together under the gate calculators category, and the how deep should a 6 foot fence post be and how to brace a sagging fence gate guides are worth reading before the posts go in the ground, since both the depth decision and the bracing decision are far easier to get right before the concrete cures than after.
Häufig gestellte Fragen
Wann ist ein 14x14 cm Pfosten erforderlich?
Für jeden Torflügel über 1,2 m Breite, geschlossene Sichtschutztore über 1,5 m Höhe oder Torgewichte über 45 kg.
Wie tief muss ein Torpfosten einbetoniert werden?
Mindestens 80 bis 100 cm frostsicher in Beton, ca. 20 bis 30 cm tiefer als normale Zaunpfosten.
Wie viel Beton braucht ein Torpfostenloch?
Ein 35 cm weites und 90 cm tiefes Fundamentloch benötigt 5 bis 6 Sack Fertigestrich a 25 kg.
Sind Stahlpfosten für Tore besser als Holz?
Ja, verzinkte Stahlrohre (mindestens 80x80 oder 100x100 mm) verziehen sich nicht bei Witterungsschwankungen.
Warum neigen sich Torpfosten häufig mit den Jahren?
Das permanente Hebelgewicht des Flugels erzeugt ein Kippmoment. Zu fläche Fundamente weichen im feuchten Erdreich auf.
Wann darf das Tor nach dem Betonieren montiert werden?
Mindestens 48 bis 72 Stunden warten, damit der Beton seine statische Druckfestigkeit erreicht.
Bringt ein Torbogen oder Uberwurfriegel oben etwas?
Sehr viel. Ein oberer Verbindungsbalken oder Bogen schließt den Kraftkreis und verhindert das Absinken der Pfosten vollständig.
Welche Schrauben für Torkloben am Pfosten wählen?
Verzinkte Schlossschrauben M10 oder M12 mit Unterlegscheiben, die komplett durch den Pfosten geschraubt werden.