Vai al contenuto principale
Fence Calculator

Calcolatore campate e moduli di recinzione

Calcola pannelli interi, misura dell'ultimo spezzone da tagliare, detrazioni dei cancelli e montanti complessivi.

Campate e pannelli recinzione

Inserisci le tue misure e il risultato si aggiorna mentre digiti.

Panoramica

I pannelli modulari consentono una posa velocissima, ma i perimetri di proprietà quasi mai misurano un multiplo perfetto di 2 metri.

Questo strumento calcola quanti pannelli interi acquistare e l'esatta misura alla quale andrà accorciato il modulo conclusivo.

Ipotesi

  • Panel widths are standard commercial 8-foot or 6-foot factory modules.
  • Gate deductions subtract the total clear opening width including post clearances.
  • Net run divides into full uncut sections and one final custom-trimmed end section.
  • Total post count accounts for continuous boundary runs.

Errori comuni

  • Ordinare i pannelli senza aver prima decurtato la misura dei passaggi e dei cancelli pedonali e carrai.
  • Gettare gli scarti dei pannelli tagliati che possono tornare utili per brevi rientranze o chiusure di aiuole.
  • Dimenticare il palo finale indispensabile a completare l'ultima campata indipendente.
  • Pretendere di montare pannelli rigidi su terreni scoscesi senza prevedere una posa a gradoni sfalsati.

Guide approfondite

Guida all’acquisto

A fence section calculator exists because prefabricated panels come in fixed factory widths, almost always 8 feet or 6 feet, while real property lines almost never divide evenly into those increments. The calculator takes a total run and a panel width and returns three things: how many full, uncut panels fit the main run, how long the leftover custom-cut end section needs to be, and how many posts the whole layout requires. That last number is easy to undercount by hand, because every section, full or trimmed, needs a post at each end, which means a run of full panels plus one terminal post closes out the count, not simply one post per panel. Getting this right before ordering material matters more with prefabricated panels than with stick-built fencing, since a missed post means a panel with no support on one side, and a miscounted end section means either a panel cut too short to close the gap or one bought and never used, either of which turns a quick panel install into a second trip to the supply yard.

Gate openings have to come out of the run before the panel count is set, not after, because panel count and gate width are solved together rather than separately. A 4 foot walk gate and an 8 foot double gate together remove 12 feet from the boundary run, and that subtraction changes how many full panels the remaining footage divides into and how long the trimmed end section comes out to. Skipping that step, or subtracting gate widths from a finished panel order instead of from the run before dividing, is one of the more common ways a prefab fence project ends up with an extra panel sitting unused, or short of coverage somewhere else along the line, neither of which is obvious until the panels are already on site. The fence perimeter calculator and the linear feet calculator are both useful upstream of this one for getting the total run right in the first place, whether the lot is a simple rectangle or an irregular boundary measured segment by segment.

The trimmed end section is not wasted material by default. A prefabricated wood panel can be cut down with a circular saw through the backer rails between pickets, provided the pickets nearest the cut get a couple of extra nails or screws to keep them secure once the rail no longer runs the panel's full original length. Vinyl panels can also be trimmed, though the horizontal rails need a fine-tooth blade and a vinyl notching tool afterward to re-cut the locking tabs that let the rail seat into the post channel, since a straight saw cut alone leaves the tab geometry wrong for a clean fit. Leftover cutoffs from either material are worth keeping rather than discarding, since a short offcut is often exactly the right length for a garden enclosure, a short return run along a house wall, or a future repair section, and cutting a fresh board for those jobs later is more wasteful than storing a piece that already exists.

Post spacing within a panel system follows the panel width directly, which is a simpler relationship than the variable spacing used in stick-built fencing, and the fence post spacing calculator is the tool to reach for when spacing needs adjusting away from the standard panel increment, for instance on a custom metal or composite system. The fence picket spacing calculator picks up the board-and-gap math within an individual section once the section lengths from this calculator are set, which matters most on picket and shadowbox styles where even gaps are part of the finished look. For posts themselves, the fence post calculator and the fence rail calculator extend this section-by-section count into full post and rail quantities including corner and gate posts. Corners in a panel system do not need an extra panel at all, just a corner post accepting rail from two directions with mitered rail ends at the 90 degree joint. The practical side of measuring a yard before any of this math starts is covered in how to measure your yard for a fence and how many posts for a fence, installation sequencing for a full wood build is in the wood fence installation guide, and boundary and setback rules that affect where a section run can start are in the property line and setback guide. The rest of the measurement calculators, including perimeter and linear feet, are on the measurement calculators hub. It is worth dry-fitting the last, trimmed section before fastening anything permanently, standing the cut panel in place against its posts, since a run measured accurately on paper can still turn up an unexpected few inches of slack or shortfall once the actual posts are set in the ground, and catching that at the dry-fit stage is far cheaper than discovering it after the panel is nailed on.

Domande frequenti

Quanti pannelli da 2 m servono per 30 metri di recinto?

Servono esattamente 15 pannelli da 2 metri (30 / 2 = 15) e 16 pali di sostegno in tratta continua.

Cosa fare se la misura non e un multiplo preciso?

Si comprano pannelli interi per la tratta principale e sull'ultimo modulo si rifilano i correnti e le assi a misura esatta.

La luce dei cancelli va sottratta dal calcolo?

Si. Un cancelletto da 1 metro e un passo carraio da 3 metri risparmiano 4 metri di pannelli da acquistare.

E difficile tagliare a metà un pannello in legno?

No, basta tagliare le traverse orizzontali con una sega circolare e rinforzare con viti le assi adiacenti al taglio.

Si possono accorciare i moduli in PVC?

Sì, usando un seghetto a denti fitti e riproducendo con pinze per asole le alette d'arresto sui correnti tagliati.

Quanti pali occorrono per un singolo modulo?

Due montanti per un modulo isolato; in una fila continua ogni pannello supplementare richiede un solo palo in più.

Qual e la larghezza standard dei pannelli in commercio?

In Europa 1.8 metri (180 cm) e 2.0 metri (200 cm) sono le dimensioni più consuete per legno, metallo e compositi.

Come si esegue un cambio di direzione a 90 gradi?

Il palo d angolo accoglie le staffe di fissaggio su due facce ortogonali senza necessità di moduli particolari.